Publication: Effect of Palatal Metal Collar’s Height on Fracture Resistance of Single Metal-Ceramic Crowns
dc.contributor.author | Elbishari, Haitham | |
dc.date.accessioned | 2023-04-25T08:07:39Z | |
dc.date.available | 2023-04-25T08:07:39Z | |
dc.date.issued | 2022 | |
dc.description.abstract | Objectives. Thee purpose of this study is to evaluate the effect of the palatal metal collar height on the fracture resistance of metal ceramic crowns. Materials and Methods. A maxillary premolar typodont tooth was prepared and scanned to fabricate 48 metal analogs. The analogs were then scanned to fabricate metal copings divided into 4 groups according to palatal metal collar height as follows; (C0): 0 mm, (C1): 1.0 mm, (C2): 1.5 mm, and (C3): 2.0 mm. After a standard application of pressed ceramic, each crown was cemented onto its corresponding metal tooth analog. The crown-analog assembly was subjected to a sequence of thermal stressing for 5,000 cycles. A universal testing machine applied controlled loads to the crowns until fracture. Examination under a stereomicroscope determined the failure mode. A scanning electron microscope (SEM) was used to examine fracture. Load to failure data was analysed using ANOVA followed by Tukey HSD (P ≤ 0.05). Results. ANOVA statistics revealed that groups with a palatal metal collar presented significantly higher failure loads when compared to the collarless group (P < 0.0001). Difference in failure loads between 1.5-mm and 2.0-mm palatal metal collar height were not statistically significant (P ¬ 0.935). ere were no significant differences detected among the groups in terms of failure mode. Conclusions: The height of the palatal metal collar has an effect on the fracture resistance of the metal-ceramic crowns. Clinical Relevance. The incorporation of a palatal collar with a predetermined height is essential to reduce the mechanical failure of metal-ceramic crowns. Clinical Relevance: The incorporation of a palatal collar with a predetermined height is essential to reduce the mechanical failure of metal-ceramic crowns. | en_US |
dc.identifier.other | 304-2022.24 | |
dc.identifier.uri | https://repository.mbru.ac.ae/handle/1/1170 | |
dc.language.iso | en | en_US |
dc.subject | Palatal metal collar | en_US |
dc.subject | Fracture Resistance | en_US |
dc.subject | Single Metal-Ceramic Crowns | en_US |
dc.title | Effect of Palatal Metal Collar’s Height on Fracture Resistance of Single Metal-Ceramic Crowns | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |