This is a staging instance. Full-text downloads are disabled.
 

Publication:
Effect from Autoclave Sterilization and Usage on the Fracture Resistance of Heat-Treated Nickel–Titanium Rotary Files

dc.contributor.authorEl Abed, Rashid
dc.contributor.authorAlshehhi, Aisha
dc.contributor.authorAlkhatib, Zuhair
dc.contributor.authorHassan Khamis, Amar
dc.contributor.authorJamal, Mohamed
dc.date.accessioned2023-08-17T05:34:16Z
dc.date.available2023-08-17T05:34:16Z
dc.date.issued2023
dc.description.abstractAbstract: This study aimed to assess the effect of mechanical loading and heating on the cyclic fatigue and torsional fracture resistances of heat-treated nickel–titanium files after usage and autoclaving. Sixty files (One Curve) were tested for cyclic fatigue and torsional fracture resistances using customized devices. The files were divided into three groups according to the test conditions (n = 10); new (group-N), used for simulated canal shaping (group-U), and sterilized after use (group-S). For cyclic fatigue resistances, the files were freely rotated in a curved metal canal under body temperature; the time elapsed to fracture was recorded and the numbers of cycles to fracture (NCF) were calculated. For the torsional resistances, the file tip was fixed and rotated until the file fractured. The maximum torsional load and distortion angle were recorded. The toughness was calculated. Fracture fragments were examined with a scanning electron microscope. Data were analyzed using a one-way analysis of variance and Tukey’s post hoc test at the significance level of 95%. Group-U showed significantly higher NCF than group-S (p < 0.05). However, there was no significant differences between groups-N and -S in the NCF (p > 0.05). Group-N showed a significantly bigger distortional angle and higher torsional toughness than groups-U and -S, but the ultimate torsional strength did not have significant difference between the groups. Under the limitation of this study, autoclave sterilization after single-usage did not improve the fracture resistance of heat-treated One Curve nickel–titanium files.en_US
dc.identifier.other304-2023.16
dc.identifier.urihttps://repository.mbru.ac.ae/handle/1/1322
dc.language.isoenen_US
dc.subjectAutoclave Sterilizationen_US
dc.subjectDynamic Fatigueen_US
dc.subjectFracture Resistanceen_US
dc.subjectHeat Treatmenten_US
dc.subjectNickel– Titanium Fileen_US
dc.subjectTorsional Strengthen_US
dc.titleEffect from Autoclave Sterilization and Usage on the Fracture Resistance of Heat-Treated Nickel–Titanium Rotary Filesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files