Convergence angles of all-ceramic full crown preparations performed in Dubai private practice

dc.contributor.authorAbdulla, Fahad
dc.contributor.authorHassan Khamis, Amar
dc.contributor.authorMilosevic, Alexander
dc.contributor.authorAbuzayda, Moosa
dc.date.accessioned2021-10-12T06:38:17Z
dc.date.available2021-10-12T06:38:17Z
dc.date.issued2018-12-01
dc.description.abstractBackground: This study aimed to determine the degree of taper and total occlusal convergence angles (TOC) for all-ceramic bonded crown preparations carried out by private practitioners in Dubai, UAE. Material and Methods: A convenience sample of all-ceramic crown preparations carried out by private dental practitioners were scanned (Carestream CS 3500) from casts and the digital images assessed. The degree of taper was measured on the axial walls of each crown preparation and the bucco-lingual and mesio-distal convergence angles subsequently calculated. Results: A total of 154 dentists prepared a total of 206 crown preparations (72 anterior, 134 posterior). The mean convergence angles mesio-distally for all preparations was 24.6° (sd 11.8º), and for the bucco-lingual it was 32.6° (sd 15.3°). The mean TOC was 28.6°. In anterior preparations, the mean bucco-lingual convergence angle was 38.8° (sd 12.2°) compared to 29.3° (sd 15.5°) for posterior preparations (p<0.001). Mean mesio-distal convergence anteriorly was 20.6° (sd 10.18°) compared to 26.7° (sd 12.16°) posteriorly (p<0.001). Distal and buccal taper were significantly greater on posterior teeth (<0.001) compared to anteriors whereas lingual taper was greater on anterior teeth (p<0.001). Mesial taper was not different. Premolars had significantly lower convergence values compared to other teeth. Conclusions: Bucco-lingual and mesio-distal convergence angles significantly exceeded the clinically acceptable convergence angle of between 10° and 22°. Greater axial taper is recommended for resin bonded all-ceramic crowns but reliance on adhesion in such preparations rather than parallelism may reduce retention and have increased biologic cost to pulp health.en_US
dc.identifier.other304-2018.22
dc.identifier.urihttps://repository.mbru.ac.ae/handle/1/545
dc.language.isoenen_US
dc.subjectAll-ceramic crown preparationsen_US
dc.subjectConvergence anglesen_US
dc.subjectAxial taperen_US
dc.titleConvergence angles of all-ceramic full crown preparations performed in Dubai private practiceen_US
dc.typeArticleen_US
dspace.entity.typePublication