This is a staging instance. Full-text downloads are disabled.
 

Publication:
Electrocardiographic markers of subclinical atrial fibrillation detected by implantable loop recorder: insights from the LOOP Study

dc.contributor.authorKrieger, Derk W.
dc.date.accessioned2023-08-17T04:22:40Z
dc.date.available2023-08-17T04:22:40Z
dc.date.issued2023
dc.description.abstractAims: Insights into subclinical atrial fibrillation (AF) development are warranted to inform the strategies of screening and subsequent clinical management upon AF detection. Hence, this study sought to characterize the onset and progression of subclinical AF with respect to 12-lead electrocardiogram (ECG) parameters. Methods and results: We included AF-naïve individuals aged 70–90 years with additional stroke risk factors who underwent implantable loop recorder (ILR) monitoring in the LOOP Study. Using data from daily ILR recordings and the computerized analysis of baseline ECG, we studied empirically selected ECG parameters for AF detection (≥6 min), cumulative AF burden, long-lasting AF (≥24 h), and AF progression. Of 1370 individuals included, 419 (30.6%) developed AF during follow-up, with a mean cumulative AF burden of 1.5% [95% CI: 1.2–1.8]. Several P-wave-related and ventricular ECG parameters were associated with new-onset AF and with cumulative AF burden in AF patients. P-wave duration (PWD), P-wave terminal force in Lead V1, and interatrial block (IAB) further demonstrated significant associations with long-lasting AF. Among AF patients, we observed an overall reduction in cumulative AF burden over time (IRR 0.70 [95% CI: 0.51–0.96]), whereas IAB was related to an increased risk of progression to AF ≥24 h (HR 1.86 [95% CI: 1.02–3.39]). Further spline analysis also revealed longer PWD to be associated with this progression in AF duration. Conclusion: We identified several ECG parameters associated with new-onset subclinical AF detected by ILR. Especially PWD and IAB were robustly related to the onset and the burden of AF as well as progression over time.en_US
dc.identifier.other204-2023.68
dc.identifier.urihttps://repository.mbru.ac.ae/handle/1/1293
dc.language.isoenen_US
dc.subjectAtrial Fibrillationen_US
dc.subjectElectrocardiographyen_US
dc.subjectP-waveen_US
dc.subjectCardiac Arrhythmiasen_US
dc.subjectStrokeen_US
dc.titleElectrocardiographic markers of subclinical atrial fibrillation detected by implantable loop recorder: insights from the LOOP Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files